{"id":18237,"date":"2026-10-04T17:39:46","date_gmt":"2026-10-04T20:39:46","guid":{"rendered":"https:\/\/arkmeds.com\/?p=18237"},"modified":"2026-10-13T22:04:26","modified_gmt":"2026-10-14T01:04:26","slug":"lown-defibrillator-cardioverter-traceability","status":"publish","type":"post","link":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/","title":{"rendered":"Defibrillators and cardioverters: what to record for each test"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"18237\" class=\"elementor elementor-18237 elementor-18056\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dacc50f e-flex e-con-boxed e-con e-parent\" data-id=\"dacc50f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-339563bd elementor-widget elementor-widget-text-editor\" data-id=\"339563bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<style>.ark-research{--ark-teal:#0097A9;--ark-slate:#244C5A;--ark-yellow:#FFC72C;font-family:Montserrat,Arial,sans-serif;color:#244C5A;max-width:900px;margin:0 auto;font-size:18px;line-height:1.85;text-align:left}\n.ark-research *{box-sizing:border-box}.ark-research p{margin:0 0 1.4em}.ark-research h2{font-size:clamp(24px,3.2vw,34px);line-height:1.3;font-weight:700;color:#244C5A;text-transform:none!important;margin:2.6em 0 .8em;scroll-margin-top:100px}.ark-research a{color:#007A89;text-decoration:underline;text-underline-offset:4px;transition:color .15s ease}.ark-research a:hover,.ark-research a:focus{color:#244C5A}.ark-research .ark-byline{font-size:15px;line-height:1.65;margin:0 0 24px;padding-bottom:20px;border-bottom:2px solid #0097A9}.ark-research .ark-lead{font-size:clamp(20px,2.3vw,24px);line-height:1.65;font-weight:500}.ark-research .ark-photo-note{font-size:13px;line-height:1.6;color:#536D76;margin:0 0 28px}.ark-research .ark-toc{font-size:15px;margin:32px 0 48px;padding:22px 0;border-top:1px solid #D7EBEE;border-bottom:1px solid #D7EBEE}.ark-research .ark-toc ol{margin:10px 0 0;padding-left:22px}.ark-research .ark-toc li{padding:3px 0}.ark-research figure{margin:36px 0}.ark-research figure img{width:100%;height:auto;display:block;border-radius:0}.ark-research figcaption{font-size:13px;line-height:1.65;color:#536D76;margin-top:16px}.ark-research .ark-chart{padding:28px 0;border-top:3px solid #0097A9;border-bottom:1px solid #D7EBEE}.ark-research .ark-chart-title{font-size:20px;font-weight:650;margin-bottom:24px}.ark-research .ark-bar-row{display:grid;grid-template-columns:minmax(140px,1fr) 2fr 80px;align-items:center;gap:18px;margin:20px 0;font-size:15px;line-height:1.45}.ark-research .ark-track{height:27px;background:#EAF2F3}.ark-research .ark-fill{display:block;height:100%;background:#0097A9}.ark-research .ark-fill.yellow{background:#FFC72C}.ark-research .ark-bar-value{font-size:25px;font-weight:700}.ark-research .ark-waffle{display:grid;grid-template-columns:repeat(5,1fr);gap:8px;width:290px;max-width:100%;flex:0 1 290px}.ark-research .ark-square{height:32px;background:#D7EBEE}.ark-research .ark-square.cord{background:#0097A9}.ark-research .ark-failure{display:flex;gap:38px;align-items:center;flex-wrap:wrap}.ark-research .ark-failure strong{font-size:56px;font-weight:750;line-height:1.1;display:block}.ark-research .ark-failure span{font-size:14px;display:block}.ark-research .ark-failure p{margin:14px 0;font-size:15px;line-height:1.6}.ark-research .ark-note{border-left:4px solid #FFC72C;padding:4px 0 4px 24px;margin:30px 0}.ark-research .ark-record{list-style:none;padding:0;margin:24px 0;counter-reset:ark-record}.ark-research .ark-record li{counter-increment:ark-record;padding:18px 0 18px 44px;border-bottom:1px solid #D7EBEE;position:relative;line-height:1.7}.ark-research .ark-record li:before{content:counter(ark-record,decimal-leading-zero);color:#007A89;font-weight:700;position:absolute;left:0;top:18px}.ark-research .ark-flow{display:grid;grid-template-columns:repeat(4,1fr);gap:20px;padding:24px 0;border-top:3px solid #0097A9}.ark-research .ark-flow b{font-size:15px;line-height:1.5;display:block}.ark-research .ark-flow span{display:block;font-size:12px;color:#007A89;letter-spacing:.1em;margin-bottom:10px}.ark-research .ark-product{display:grid;grid-template-columns:280px 1fr;gap:32px;align-items:center}.ark-research .ark-product img{max-width:280px;width:100%;height:auto;margin:0 auto}.ark-research .ark-product p{font-size:16px;line-height:1.8}.ark-research details{border-bottom:1px solid #D7EBEE;padding:20px 0}.ark-research summary{font-size:17px;font-weight:650;cursor:pointer;line-height:1.6}.ark-research details p{font-size:16px;margin:16px 0 0}.ark-research .ark-sources{font-size:14px;line-height:1.8;overflow-wrap:anywhere}.ark-research .ark-sources li{margin:14px 0}.ark-research .ark-credit{font-size:13px;line-height:1.7;border-top:1px solid #D7EBEE;padding-top:20px;margin-top:28px}\n@media(max-width:600px){.ark-research{font-size:17px}.ark-research .ark-bar-row{grid-template-columns:1fr 74px;gap:12px}.ark-research .ark-bar-label{grid-column:1\/-1}.ark-research .ark-product{grid-template-columns:1fr;gap:12px}.ark-research .ark-product img{max-width:250px}.ark-research .ark-flow{grid-template-columns:repeat(2,1fr)}.ark-research .ark-failure{gap:24px}}\n@media(prefers-reduced-motion:reduce){.ark-research a{transition:none}}\n\n.ark-research{line-height:1.8}.ark-research strong{font-weight:700}.ark-research .ark-byline time{font-size:13px;font-weight:400;color:#536D76}.ark-research .ark-answer{border-left:4px solid #FFC72C;padding:4px 0 4px 24px;margin:28px 0 32px}.ark-research .ark-answer p:last-child{margin-bottom:0}.ark-research .ark-answer-label{font-size:13px;font-weight:700;letter-spacing:.035em;margin-bottom:12px;text-transform:uppercase}.ark-research .ark-table-scroll{width:100%;overflow-x:auto;margin:26px 0 32px}.ark-research .ark-table-scroll:focus-visible{outline:2px solid #0097A9;outline-offset:4px}.ark-research table{border-collapse:collapse;width:100%;font-size:15px;line-height:1.65;text-align:left}.ark-research th,.ark-research td{padding:17px 15px;vertical-align:top;border-bottom:1px solid #D7EBEE}.ark-research thead th{background:#EAF2F3;border-top:3px solid #0097A9;font-weight:700}.ark-research tbody th{font-weight:650;min-width:125px}.ark-research table:has(th:nth-child(3)){min-width:550px}.ark-research .ark-ref{font-size:14px;white-space:nowrap}.ark-research .ark-toc{margin-bottom:36px}.ark-research .ark-toc li{padding:4px 0}.ark-research .ark-credit{font-size:13px}.ark-research .ark-photo-note a{white-space:nowrap}\n@media(max-width:600px){.ark-research .ark-answer{padding-left:18px}.ark-research th,.ark-research td{padding:14px 11px}.ark-research table{font-size:14px}.ark-research tbody th{min-width:105px}.ark-research .ark-product figure{margin-bottom:12px}}\n\n.ark-research .ark-takeaways{padding-left:25px;margin:24px 0}.ark-research .ark-takeaways li{padding:8px 0 16px;line-height:1.75}\n.ark-research .ark-product-steps{padding-left:28px;margin:24px 0}.ark-research .ark-product-steps li{padding:7px 0 12px}.ark-research .ark-product-cta{display:inline-block;max-width:100%;padding:14px 20px;min-height:44px;background:#244C5A;color:#fff;font-size:16px;font-weight:650;line-height:1.6;text-decoration:none}.ark-research .ark-product-cta:hover,.ark-research .ark-product-cta:focus{background:#244C5A;color:#FFC72C}.ark-research .ark-product-cta:focus-visible{outline:3px solid #FFC72C;outline-offset:4px}.ark-research .ark-product img{height:auto;object-fit:contain}\n\n.ark-research h3{font-size:21px;line-height:1.4;margin:30px 0 16px}.ark-research .ark-bar-value{font-size:20px}.ark-research .ark-bar-row{grid-template-columns:minmax(145px,1fr) 1.5fr minmax(90px,auto)}@media(max-width:600px){.ark-research .ark-bar-row{grid-template-columns:1fr 95px}}\n.ark-research div.ark-product-cta{display:block;padding:26px 28px;margin:30px 0;font-weight:400;color:#fff}.ark-research div.ark-product-cta h3{margin:0 0 12px;color:#fff}.ark-research div.ark-product-cta p{margin:0 0 20px;color:#fff}.ark-research div.ark-product-cta a{display:inline-block;padding:12px 18px;background:#FFC72C;color:#244C5A;text-decoration:none;font-weight:700;min-height:44px}.ark-research div.ark-product-cta a:focus-visible{outline:3px solid #fff;outline-offset:5px}.ark-research .ark-product-photo img{margin:0 auto}.ark-research .ark-product-photo figcaption{text-align:left}.ark-research .ark-chart-scale{font-size:12px;color:#536D76;margin-top:16px}.ark-research .ark-fill{max-width:100%}\n\nbody.single-post h1.elementor-heading-title{text-transform:none!important}\n.ark-research .ark-toc a{display:block}\n@media(max-width:600px){.ark-research .ark-toc a{min-height:44px}}\n\n.ark-research .ark-chart img{max-width:560px;margin:0 auto}\n<\/style>\n<article class=\"ark-research\" lang=\"en\"><p class=\"ark-byline\">By <strong>Thiago Bajur<\/strong> \u00b7 CEO, Arkmeds<\/p><p class=\"ark-photo-note\">Cover: conceptual AI-generated illustration following the Arkmeds identity. It does not depict an actual test or measurement.<\/p><p>A defibrillator or cardioverter test record needs to show which unit was assessed, what was performed and which results support the conclusion. In this article, we use the Lown analyzer and Mark II app from Arkmeds as examples of how to organize these records. Conditions, limitations and outstanding issues also need to remain in the history to support the next technical decision.<\/p><nav class=\"ark-toc\" aria-label=\"In this article\"><strong>In this article<\/strong><ol><li><a href=\"#does-normal-operation-mean-readiness-for-use\">Does normal operation mean readiness for use?<\/a><\/li><li><a href=\"#are-document-traceability-and-metrological-traceability-the-same\">Are document traceability and metrological traceability the same?<\/a><\/li><li><a href=\"#what-should-be-recorded-in-a-defibrillator-test\">What should be recorded in a defibrillator test?<\/a><\/li><li><a href=\"#which-standard-should-appear-in-the-report\">Which standard should appear in the report?<\/a><\/li><li><a href=\"#how-can-an-issue-be-recorded-without-hiding-the-scope\">How can an issue be recorded without hiding the scope?<\/a><\/li><li><a href=\"#where-do-lown-and-mark-ii-support-this-flow\">Where do Lown and Mark II support this flow?<\/a><\/li><li><a href=\"#what-should-be-checked-before-comparing-two-reports\">What should be checked before comparing two reports?<\/a><\/li><li><a href=\"#how-can-a-report-be-corrected-without-losing-its-history\">How can a report be corrected without losing its history?<\/a><\/li><li><a href=\"#where-can-you-become-more-familiar-with-lown\">Where can you become more familiar with Lown?<\/a><\/li><\/ol><\/nav>\n<p>Imagine receiving \u201cdefibrillator OK\u201d on a work order. Does that tell you that an energy test was performed? That the electrode pads are within their expiry date? That the device can be accessed at night? These are different questions. A useful record lets someone find the answer without relying on the memory of the person who visited the site.<\/p>\n<h2 id=\"does-normal-operation-mean-readiness-for-use\">Does normal operation mean readiness for use?<\/h2>\n<p>Not necessarily. <a href=\"https:\/\/doi.org\/10.1038\/s41598-022-14611-1\">Kim and colleagues<\/a> analyzed annual inspections of city-funded public AEDs in Seoul between 2013 and 2017. The dataset accumulates <strong>23,619 inspection records<\/strong> and should not be treated as a count of unique devices. Operation, accessories and access were observed separately.<\/p>\n<figure class=\"ark-chart\"><img loading=\"lazy\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/arkmeds.com\/wp-content\/uploads\/2026\/10\/arkmeds-lown-inspecoes-en.png\" alt=\"Overlapping conditions in 23,619 Seoul inspection records: normal operation 96.9%, valid electrodes 87.1%, 24-hour access 66.8%\" width=\"960\" height=\"1360\"><figcaption>Original visualization of the total column in Kim et al. (2022), Table 3, Seoul, 2013\u20132017. Percentages rounded to one decimal place; factors overlap. The table below preserves counts. Not an energy test or a Lown effect.<\/figcaption><\/figure>\n<div class=\"ark-table-scroll\" tabindex=\"0\" role=\"region\" id=\"lown-table-1\" aria-label=\"Does normal operation mean readiness for use?\"><table><thead><tr><th scope=\"col\">Condition recorded in the study<\/th><th scope=\"col\">Records \/ total<\/th><th scope=\"col\">Percentage, one decimal place<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Normal operation<\/th><td>22,893 \/ 23,619<\/td><td>96.9%<\/td><\/tr><tr><th scope=\"row\">Electrodes within expiry date<\/th><td>20,578 \/ 23,619<\/td><td>87.1%<\/td><\/tr><tr><th scope=\"row\">24-hour access<\/th><td>15,771 \/ 23,619<\/td><td>66.8%<\/td><\/tr><\/tbody><\/table><\/div>\n<p>The bars <strong>overlap and must not be added together<\/strong>. The same record may meet more than one condition. The study defined readiness as normal operation, good battery status and valid electrodes; 24-hour usability added access throughout that period. In Table 4, 3,646 records (15.4%) were classified as not ready, and 10,422 (44.1%) as lacking 24-hour usability.<\/p>\n<p>This changes the management question: as well as \u201cis there a report?\u201d, ask <strong>\u201cwhich condition still prevents availability?\u201d<\/strong> The study\u2019s on-site inspection was not an instrumented energy test. Its numbers do not estimate risk during an emergency, describe Brazilian hospital cardioverters or establish an effect of Lown or a CMMS. Limitations include the introduction of new devices and variation in inspectors over the years.<\/p>\n<p> The publication contains discrepancies between some counts and percentages across its tables. This summary preserves the selected totals from Table 3 and the overall classifications from Table 4; it does not use them to reconstruct the distribution of causes.<\/p>\n<h2 id=\"are-document-traceability-and-metrological-traceability-the-same\">Are document traceability and metrological traceability the same?<\/h2>\n<p>The <a href=\"https:\/\/jcgm.bipm.org\/vim\/en\/2.41.html\">VIM, entry 2.41<\/a>, defines metrological traceability as a property of a measurement result: it can be related to a reference through a documented, unbroken chain of calibrations, each contributing to uncertainty. The vocabulary itself distinguishes this concept from the history of documents or instruments.<\/p>\n<div class=\"ark-table-scroll\" tabindex=\"0\" role=\"region\" id=\"lown-table-2\" aria-label=\"Are document traceability and metrological traceability the same?\"><table><thead><tr><th scope=\"col\">Concept<\/th><th scope=\"col\">Question it answers<\/th><th scope=\"col\">Evidence needed<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Document traceability<\/th><td>Which asset and service produced this record?<\/td><td>Identification, date, responsible person, version and retrievable links<\/td><\/tr><tr><th scope=\"row\">Metrological traceability<\/th><td>To which reference does the measurement result relate?<\/td><td>Calibration chain, relevant references and uncertainties<\/td><\/tr><tr><th scope=\"row\">Readiness and availability<\/th><td>Which conditions were checked and which still need action?<\/td><td>Documented scope, accessories, location, access and outstanding issues<\/td><\/tr><\/tbody><\/table><\/div>\n<p><strong>Bluetooth or a QR code alone does not demonstrate metrological traceability.<\/strong> They help transfer and retrieve the record. Instrument status and measurement suitability require their own evidence. Even metrological traceability does not automatically establish that uncertainty is suitable for the purpose, as VIM note 5 explains.<\/p>\n<h2 id=\"what-should-be-recorded-in-a-defibrillator-test\">What should be recorded in a defibrillator test?<\/h2>\n<p>The <a href=\"https:\/\/assets.publishing.service.gov.uk\/media\/6089dc938fa8f51b91f3d82f\/Managing_medical_devices.pdf\">MHRA\u2019s 2021 guidance<\/a> recommends retrievable records, device identification and preservation of history (\u00a72.4). It also discusses test instruments maintained and calibrated as required, and appropriate assessment before return to service (\u00a78.7). This is UK management guidance; the following table is an adaptable editorial synthesis, not an official form or a universal legal requirement.<\/p>\n<div class=\"ark-table-scroll\" tabindex=\"0\" role=\"region\" id=\"lown-table-3\" aria-label=\"What should be recorded in a defibrillator test?\"><table><thead><tr><th scope=\"col\">Record section<\/th><th scope=\"col\">What to preserve<\/th><th scope=\"col\">Why it matters<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">Identity<\/th><td>Model, serial number, asset ID and work order<\/td><td>Avoids assigning results to the wrong unit<\/td><\/tr><tr><th scope=\"row\">Instrument<\/th><td>Analyzer identification and relevant metrological documentation<\/td><td>Allows the reference used to be retrieved<\/td><\/tr><tr><th scope=\"row\">Scope<\/th><td>Functions assessed, work not performed and reasons<\/td><td>Avoids conclusions about functions that were not tested<\/td><\/tr><tr><th scope=\"row\">Procedure<\/th><td>Document, version and applicable criteria<\/td><td>Makes the conclusion reviewable by another person<\/td><\/tr><tr><th scope=\"row\">Conditions and results<\/th><td>Relevant configuration, units, readings and observations<\/td><td>Supports interpretation and comparison<\/td><\/tr><tr><th scope=\"row\">Conclusion<\/th><td>Criterion applied, limitations, responsible person and next action<\/td><td>Links the result to the technical decision<\/td><\/tr><tr><th scope=\"row\">Follow-up<\/th><td>Issue, responsible person, deadline and resolution evidence<\/td><td>Keeps an observation from being lost after delivery<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Selecting an energy value and writing \u201cpassed\u201d is insufficient. Configuration context, the applicable criterion and the scope performed must accompany the conclusion. When monitoring trends, <strong>confirm comparability before interpreting differences<\/strong>: a change in procedure, accessory or condition may change a reading without demonstrating equipment deterioration.<\/p>\n<h2 id=\"which-standard-should-appear-in-the-report\">Which standard should appear in the report?<\/h2>\n<p>The standard named must match the work performed. In the IEC catalogue, <strong>IEC 60601-2-4<\/strong> covers particular requirements for basic safety and essential performance of cardiac defibrillators. <strong>IEC 62353:2014<\/strong> addresses recurrent and post-repair testing of medical electrical equipment. These are not interchangeable labels for any service. <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/6913\">See the IEC 62353 scope<\/a>.<\/p>\n<p>A recent update deserves attention in document control: IEC published <strong>Amendment 2 of 2026 to IEC 60601-2-4 on 28 September 2026<\/strong>. The <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/89561\">official catalogue<\/a> identifies the publication and its consolidated version. A new amendment calls for checking the team\u2019s references; its existence alone does not establish automatic applicability to every device, contract or country. The complete licensed standards were not consulted for this article; no universal energy or synchronization limits are prescribed.<\/p>\n<h2 id=\"how-can-an-issue-be-recorded-without-hiding-the-scope\">How can an issue be recorded without hiding the scope?<\/h2>\n<p>Consider this <strong>fictional documentation case<\/strong>, which represents neither a customer nor an Arkmeds measurement. A readiness visit to asset \u201cAED-FIC-017\u201d found operation indicated as normal, expired electrodes and access to the site limited to opening hours. No instrumented energy test was performed.<\/p>\n<div class=\"ark-table-scroll\" tabindex=\"0\" role=\"region\" id=\"lown-table-4\" aria-label=\"How can an issue be recorded without hiding the scope?\"><table><thead><tr><th scope=\"col\">Incomplete record<\/th><th scope=\"col\">Record that supports follow-up<\/th><\/tr><\/thead><tbody><tr><th scope=\"row\">\u201cAED OK\u201d<\/th><td>Asset identification, date and scope of the readiness visit<\/td><\/tr><tr><th scope=\"row\">\u201cCheck materials\u201d<\/th><td>Expired electrodes; responsible person and next action assigned<\/td><\/tr><tr><th scope=\"row\">\u201cDevice available\u201d<\/th><td>Access hours recorded and restriction referred to management<\/td><\/tr><tr><th scope=\"row\">\u201cTest performed\u201d<\/th><td>Checks described; instrumented energy test not performed<\/td><\/tr><tr><th scope=\"row\">\u201cIssue resolved\u201d<\/th><td>Action, date and resolution evidence linked to the original record<\/td><\/tr><\/tbody><\/table><\/div>\n<p>A later performance test may add another piece of evidence to the same history. <strong>It does not remove an accessory or access restriction.<\/strong> Likewise, electrode replacement needs its own record and does not demonstrate that an energy test was performed. Conclusions and return-to-use decisions belong to the institution\u2019s technical process.<\/p>\n<h2 id=\"where-do-lown-and-mark-ii-support-this-flow\">Where do Lown and Mark II support this flow?<\/h2>\n<p>When results are separated from the work order, the team must reconstruct context to deliver the report. <a href=\"https:\/\/arkmeds.com\/en\/lown-defibrillator-analyzer\/\">Lown Arkmeds<\/a> provides functions for assessing energy, synchronization and charge time, ECG simulation and pacemaker assessment. The official product page documents Bluetooth connectivity with Mark II, checklists, PDF reports and offline execution with later synchronization.<\/p>\n<figure class=\"ark-product-photo\"><img loading=\"lazy\" loading=\"lazy\" decoding=\"async\" width=\"690\" height=\"690\" src=\"https:\/\/arkmeds.com\/wp-content\/uploads\/2026\/05\/analisador-lown-desfibrilador.png\" alt=\"Official image of Arkmeds Lown with a visible screen and transport backpack\" style=\"max-width:430px;width:100%;height:auto;margin:0 auto\"><figcaption>Official Lown product image. The screen identifies the product; it does not depict Seoul study results or the fictional case in this article.<\/figcaption><\/figure>\n<p>The practical benefit is <strong>connecting execution to the work-order record<\/strong>, reducing transcription steps and organizing delivery. A workflow can select the asset and scope, connect the analyzer to the app, perform the planned functions, review results and observations and make the report available to its recipient. If work takes place offline, confirm synchronization before announcing delivery. Report timing and the features used depend on the scope and operating configuration.<\/p>\n<figure class=\"ark-chart\"><img loading=\"lazy\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/arkmeds.com\/wp-content\/uploads\/2026\/10\/arkmeds-lown-registro-en.png\" alt=\"Editorial record flow: identify the asset, describe the scope, review results and follow up on issues\" width=\"960\" height=\"1280\"><figcaption>Editorial synthesis for organizing documentation. Adapt fields to the procedure and service; this flow is neither a standard nor a Mark II screen.<\/figcaption><\/figure>\n<p>Automation must preserve work not performed and issues that still require action. The record can feed the asset history in <a href=\"https:\/\/arkmeds.com\/en\/cmms-maintenance-management-platform\/\">Arkmeds CMMS<\/a>, with work orders and follow-up. Software organizes information; it does not turn every outstanding issue into a pass or assign a third-party study\u2019s results to the product.<\/p>\n<div class=\"ark-product-cta\"><h3>Organize tests and reports in one flow<\/h3><p>Explore Lown\u2019s features and its integration with Mark II to document your team\u2019s work.<\/p><a href=\"https:\/\/arkmeds.com\/en\/lown-defibrillator-analyzer\/\">Explore Lown<\/a><\/div>\n<h2 id=\"what-should-be-checked-before-comparing-two-reports\">What should be checked before comparing two reports?<\/h2>\n<p>Confirm that they refer to the same asset, function, procedure and relevant conditions. Locate accessory changes, interventions and criteria. Then check whether readings, units and metrological documentation support the intended comparison. <strong>A numerical difference without context is still a question, not a demonstrated trend.<\/strong><\/p>\n<h2 id=\"how-can-a-report-be-corrected-without-losing-its-history\">How can a report be corrected without losing its history?<\/h2>\n<p>Preserve the previous version and the reason for change, following the record-preservation principle in MHRA \u00a72.4. Record who made the correction, when and what information changed. <strong>Correcting the document also requires assessing its effect on the earlier conclusion.<\/strong> An incorrect unit or a link to the wrong asset may require more than issuing another PDF. The process must allow the basis of the decision to be retrieved and relevant follow-up to be tracked.<\/p>\n<h2 id=\"where-can-you-become-more-familiar-with-lown\">Where can you become more familiar with Lown?<\/h2>\n<p>The Arkmeds channel\u2019s video on <a href=\"https:\/\/www.youtube.com\/watch?v=Nfmvy2cYxuk\">preventive maintenance and calibration of defibrillators and cardioverters<\/a> can support familiarization with the solution. The presentation is in Brazilian Portuguese. To perform servicing, use the device manufacturer\u2019s documentation and the <a href=\"https:\/\/arkmeds.com\/en\/analyzer-manuals\/\">official Arkmeds analyzer manuals section<\/a>, following the applicable procedure.<\/p>\n<div style=\"position:relative;aspect-ratio:16\/9;width:100%;margin:24px 0\"><iframe src=\"https:\/\/www.youtube.com\/embed\/Nfmvy2cYxuk\" title=\"Arkmeds presentation on preventive maintenance and calibration of defibrillators and cardioverters, in Brazilian Portuguese\" loading=\"lazy\" allowfullscreen style=\"border:0;width:100%;height:100%\"><\/iframe><\/div><h2 id=\"references\">Sources and further reading<\/h2><ol class=\"ark-sources\"><li><a href=\"https:\/\/doi.org\/10.1038\/s41598-022-14611-1\">Kim et al. (2022) \u2014 Trends in maintenance status and usability of public automated external defibrillators<\/a><\/li><li><a href=\"https:\/\/jcgm.bipm.org\/vim\/en\/2.41.html\">JCGM\/BIPM \u2014 VIM 3, 2.41: metrological traceability<\/a><\/li><li><a href=\"https:\/\/assets.publishing.service.gov.uk\/media\/6089dc938fa8f51b91f3d82f\/Managing_medical_devices.pdf\">MHRA (2021) \u2014 Managing Medical Devices<\/a><\/li><li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/89561\">IEC \u2014 IEC 60601-2-4:2010\/AMD2:2026, official catalogue<\/a><\/li><li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/6913\">IEC \u2014 IEC 62353:2014, official catalogue<\/a><\/li><li><a href=\"https:\/\/arkmeds.com\/en\/lown-defibrillator-analyzer\/\">Arkmeds \u2014 Lown functions and Mark II integration<\/a><\/li><li><a href=\"https:\/\/arkmeds.com\/en\/cmms-maintenance-management-platform\/\">Arkmeds \u2014 CMMS and asset history<\/a><\/li><li><a href=\"https:\/\/arkmeds.com\/en\/analyzer-manuals\/\">Arkmeds \u2014 official analyzer manuals section<\/a><\/li><li><a href=\"https:\/\/www.youtube.com\/watch?v=Nfmvy2cYxuk\">Arkmeds \u2014 familiarization video: preventive maintenance and calibration of defibrillators and cardioverters<\/a><\/li><\/ol><p class=\"ark-credit\">Research and review: 6 October 2026. Original chart based on Kim et al. (2022), published under CC BY 4.0. The flow and fictional case are editorial syntheses, not customer results. The historical publication date was preserved.<\/p><\/article>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>What to record about the unit, scope, conditions, results and outstanding issues in defibrillator and cardioverter tests, using Lown and Mark II as Arkmeds examples.<\/p>\n","protected":false},"author":1,"featured_media":18488,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":true,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[2],"tags":[],"class_list":["post-18237","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-engenharia-clinica"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Defibrillators and cardioverters: test records | Arkmeds<\/title>\n<meta name=\"description\" content=\"Explore how to record the unit, scope, conditions, results and outstanding issues for defibrillator and cardioverter tests, with Lown and Mark II examples.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Traceability for defibrillators and cardioverters with Lown\" \/>\n<meta property=\"og:description\" content=\"Connect defibrillator and cardioverter records to the right asset, test scope and results, with Lown, Mark II and a documented review process.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/\" \/>\n<meta property=\"og:site_name\" content=\"Arkmeds\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/somosarkmeds\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-04T20:39:46+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-14T01:04:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/arkmeds.com\/wp-content\/uploads\/2026\/10\/arkmeds-editorial-defibrillation.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1672\" \/>\n\t<meta property=\"og:image:height\" content=\"941\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Arkmeds Solu\u00e7\u00f5es\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Arkmeds Solu\u00e7\u00f5es\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/\"},\"author\":{\"name\":\"Arkmeds Solu\u00e7\u00f5es\",\"@id\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/#\\\/schema\\\/person\\\/421c00502dbc1f16afc5b5690209d50e\"},\"headline\":\"Defibrillators and cardioverters: what to record for each test\",\"datePublished\":\"2026-10-04T20:39:46+00:00\",\"dateModified\":\"2026-10-14T01:04:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/\"},\"wordCount\":1678,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/arkmeds.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/arkmeds-editorial-defibrillation.png\",\"articleSection\":[\"Engenharia Cl\u00ednica\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/\",\"url\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/\",\"name\":\"Defibrillators and cardioverters: test records | Arkmeds\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/arkmeds.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/arkmeds-editorial-defibrillation.png\",\"datePublished\":\"2026-10-04T20:39:46+00:00\",\"dateModified\":\"2026-10-14T01:04:26+00:00\",\"description\":\"Explore how to record the unit, scope, conditions, results and outstanding issues for defibrillator and cardioverter tests, with Lown and Mark II examples.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/#primaryimage\",\"url\":\"https:\\\/\\\/arkmeds.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/arkmeds-editorial-defibrillation.png\",\"contentUrl\":\"https:\\\/\\\/arkmeds.com\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/arkmeds-editorial-defibrillation.png\",\"width\":1672,\"height\":941,\"caption\":\"AI-generated editorial illustration. A stylized heart, graphic line and document represent defibrillation and records. It does not depict a real test, measurement, product or event.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/lown-defibrillator-cardioverter-traceability\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Defibrillators and cardioverters: what to record for each test\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/#website\",\"url\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/\",\"name\":\"Arkmeds\",\"description\":\"Gest\u00e3o de Ativos e Engenharia Cl\u00ednica Inteligente\",\"publisher\":{\"@id\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/#organization\",\"name\":\"Arkmeds\",\"url\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/arkmeds.com\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/logo.webp\",\"contentUrl\":\"https:\\\/\\\/arkmeds.com\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/logo.webp\",\"width\":1100,\"height\":241,\"caption\":\"Arkmeds\"},\"image\":{\"@id\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/somosarkmeds\",\"https:\\\/\\\/www.youtube.com\\\/@Arkmeds\",\"https:\\\/\\\/www.instagram.com\\\/somosarkmeds\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/arkmeds.com\\\/pt-br\\\/#\\\/schema\\\/person\\\/421c00502dbc1f16afc5b5690209d50e\",\"name\":\"Arkmeds Solu\u00e7\u00f5es\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7bb48a9b40a56773df74e2756bd3e22047df8d868bf36f67f8e7bf486003e361?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7bb48a9b40a56773df74e2756bd3e22047df8d868bf36f67f8e7bf486003e361?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7bb48a9b40a56773df74e2756bd3e22047df8d868bf36f67f8e7bf486003e361?s=96&d=mm&r=g\",\"caption\":\"Arkmeds Solu\u00e7\u00f5es\"},\"sameAs\":[\"http:\\\/\\\/arkmeds.com\"],\"url\":\"https:\\\/\\\/arkmeds.com\\\/en\\\/blog\\\/author\\\/arkmeds\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Defibrillators and cardioverters: test records | Arkmeds","description":"Explore how to record the unit, scope, conditions, results and outstanding issues for defibrillator and cardioverter tests, with Lown and Mark II examples.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/","og_locale":"en_US","og_type":"article","og_title":"Traceability for defibrillators and cardioverters with Lown","og_description":"Connect defibrillator and cardioverter records to the right asset, test scope and results, with Lown, Mark II and a documented review process.","og_url":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/","og_site_name":"Arkmeds","article_publisher":"https:\/\/www.facebook.com\/somosarkmeds","article_published_time":"2026-10-04T20:39:46+00:00","article_modified_time":"2026-10-14T01:04:26+00:00","og_image":[{"width":1672,"height":941,"url":"https:\/\/arkmeds.com\/wp-content\/uploads\/2026\/10\/arkmeds-editorial-defibrillation.png","type":"image\/png"}],"author":"Arkmeds Solu\u00e7\u00f5es","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Arkmeds Solu\u00e7\u00f5es","Est. reading time":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/#article","isPartOf":{"@id":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/"},"author":{"name":"Arkmeds Solu\u00e7\u00f5es","@id":"https:\/\/arkmeds.com\/pt-br\/#\/schema\/person\/421c00502dbc1f16afc5b5690209d50e"},"headline":"Defibrillators and cardioverters: what to record for each test","datePublished":"2026-10-04T20:39:46+00:00","dateModified":"2026-10-14T01:04:26+00:00","mainEntityOfPage":{"@id":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/"},"wordCount":1678,"commentCount":0,"publisher":{"@id":"https:\/\/arkmeds.com\/pt-br\/#organization"},"image":{"@id":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/#primaryimage"},"thumbnailUrl":"https:\/\/arkmeds.com\/wp-content\/uploads\/2026\/10\/arkmeds-editorial-defibrillation.png","articleSection":["Engenharia Cl\u00ednica"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/","url":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/","name":"Defibrillators and cardioverters: test records | Arkmeds","isPartOf":{"@id":"https:\/\/arkmeds.com\/pt-br\/#website"},"primaryImageOfPage":{"@id":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/#primaryimage"},"image":{"@id":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/#primaryimage"},"thumbnailUrl":"https:\/\/arkmeds.com\/wp-content\/uploads\/2026\/10\/arkmeds-editorial-defibrillation.png","datePublished":"2026-10-04T20:39:46+00:00","dateModified":"2026-10-14T01:04:26+00:00","description":"Explore how to record the unit, scope, conditions, results and outstanding issues for defibrillator and cardioverter tests, with Lown and Mark II examples.","breadcrumb":{"@id":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/#primaryimage","url":"https:\/\/arkmeds.com\/wp-content\/uploads\/2026\/10\/arkmeds-editorial-defibrillation.png","contentUrl":"https:\/\/arkmeds.com\/wp-content\/uploads\/2026\/10\/arkmeds-editorial-defibrillation.png","width":1672,"height":941,"caption":"AI-generated editorial illustration. A stylized heart, graphic line and document represent defibrillation and records. It does not depict a real test, measurement, product or event."},{"@type":"BreadcrumbList","@id":"https:\/\/arkmeds.com\/en\/blog\/lown-defibrillator-cardioverter-traceability\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/arkmeds.com\/pt-br\/"},{"@type":"ListItem","position":2,"name":"Defibrillators and cardioverters: what to record for each test"}]},{"@type":"WebSite","@id":"https:\/\/arkmeds.com\/pt-br\/#website","url":"https:\/\/arkmeds.com\/pt-br\/","name":"Arkmeds","description":"Gest\u00e3o de Ativos e Engenharia Cl\u00ednica Inteligente","publisher":{"@id":"https:\/\/arkmeds.com\/pt-br\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/arkmeds.com\/pt-br\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/arkmeds.com\/pt-br\/#organization","name":"Arkmeds","url":"https:\/\/arkmeds.com\/pt-br\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/arkmeds.com\/pt-br\/#\/schema\/logo\/image\/","url":"https:\/\/arkmeds.com\/wp-content\/uploads\/2025\/05\/logo.webp","contentUrl":"https:\/\/arkmeds.com\/wp-content\/uploads\/2025\/05\/logo.webp","width":1100,"height":241,"caption":"Arkmeds"},"image":{"@id":"https:\/\/arkmeds.com\/pt-br\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/somosarkmeds","https:\/\/www.youtube.com\/@Arkmeds","https:\/\/www.instagram.com\/somosarkmeds\/"]},{"@type":"Person","@id":"https:\/\/arkmeds.com\/pt-br\/#\/schema\/person\/421c00502dbc1f16afc5b5690209d50e","name":"Arkmeds Solu\u00e7\u00f5es","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/7bb48a9b40a56773df74e2756bd3e22047df8d868bf36f67f8e7bf486003e361?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7bb48a9b40a56773df74e2756bd3e22047df8d868bf36f67f8e7bf486003e361?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7bb48a9b40a56773df74e2756bd3e22047df8d868bf36f67f8e7bf486003e361?s=96&d=mm&r=g","caption":"Arkmeds Solu\u00e7\u00f5es"},"sameAs":["http:\/\/arkmeds.com"],"url":"https:\/\/arkmeds.com\/en\/blog\/author\/arkmeds\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/arkmeds.com\/wp-content\/uploads\/2026\/10\/arkmeds-editorial-defibrillation.png","_links":{"self":[{"href":"https:\/\/arkmeds.com\/en\/wp-json\/wp\/v2\/posts\/18237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/arkmeds.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/arkmeds.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/arkmeds.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/arkmeds.com\/en\/wp-json\/wp\/v2\/comments?post=18237"}],"version-history":[{"count":9,"href":"https:\/\/arkmeds.com\/en\/wp-json\/wp\/v2\/posts\/18237\/revisions"}],"predecessor-version":[{"id":19022,"href":"https:\/\/arkmeds.com\/en\/wp-json\/wp\/v2\/posts\/18237\/revisions\/19022"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/arkmeds.com\/en\/wp-json\/wp\/v2\/media\/18488"}],"wp:attachment":[{"href":"https:\/\/arkmeds.com\/en\/wp-json\/wp\/v2\/media?parent=18237"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/arkmeds.com\/en\/wp-json\/wp\/v2\/categories?post=18237"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/arkmeds.com\/en\/wp-json\/wp\/v2\/tags?post=18237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}